Leeson A6C17XC21 Explosion Proof Motor Specifications
- Download - A6C17XC21 Motor Connection
- Download - A6C17XC21 Motor Outline/ Drawing
- Download - A6C17XC21 Motor Performance
- Download - A6C17XC21 Motor Operation Manual
- Download - A6C17XC21 Motor Complete Data Pack
A6C17XC21 General Information
UPC
|
Weight
|
Package Length
|
Package Width
|
Package Height
|
---|---|---|---|---|
691720009567 | 34 lbs | 19.5 in | 10.44 in | 10.88 in |
A6C17XC21 Nameplate Information
Output HP
|
Frequency
|
Current
|
Service Factor
|
Efficiency
|
---|---|---|---|---|
0.75 | 60 Hz | 11.0/5.4-5.5 A | 1 | 70% |
Duty | Design Code | Frame | Thermal Protection | Drive End Bearing Size |
Continuous | N | 56C | Automatic | 6203 |
UL | CE | Hazardous Location | Output KW | Voltage |
UL Listed and CSA Certified | N | EXP PROOF CL | GR C&D CL || GR F&G T3C | 0.56 | 115/208-230 V |
Speed | Phase | Power Factor | Insulation Class | KVA Code |
1,725 rpm | 1 | 66.2 | B | L |
Enclosure | Ambient Temperature (Celsius) | Opp Drive End Bearing Size | CSA | IP Code |
Explosion Proof Fan Cooled | 40 | 6203 | Y | 54 |
A6C17XC21 Technical Information
Electrical Type | Poles | Resistance Main | Motor Operation |
---|---|---|---|
Capacitor Start Induction Run | 4 | 0 Ohms | Horizontal |
Opp Drive End Bearing | Shaft Type | Frame Length | Shaft Extension |
Ball | NEMA 56 | 7.31 in | 1.88 in |
Starting Method | Rotation | Mounting | Drive End Bearing |
Across the Line | Selective Counterclockwise | Round | Ball |
Frame Material | Overall Length | Shaft Diameter | Assembly/ Box Mounting |
Rolled Steel | 14.44 in | 0.625 in | F1 ONLY |
A6C17XC21 Speed Characteristics
Curve-Point | Current (Amps) | Current (%) | Torque (ft-lbs) | (%) | Speed (RPM) | Rated Output (KW) | Power Factor (%) | Rated Output (HP) |
---|---|---|---|---|---|---|---|---|
Break-Down | 15.80 | - | 97.90 | - | 1,500 | 2.90 | - | 0.75 |
Pull-Up | 20.50 | - | 72.60 | - | 1,229 | 3.40 | - | 0.75 |
Locked-Rotor | 30.50 | 0.0 | 133.00 | 0.0 | 0 | 6.60 | 0.0 | 0.75 |
A6C17XC21 Load Characteristics
% of Rated Load | 0% | 25% | 50% | 75% | 100% | 125% | 150% | 175% | 200% |
---|---|---|---|---|---|---|---|---|---|
Current (Amps) | 3.76 | 3.89 | 4.19 | 4.64 | 5.50 | 5.95 | 6.82 | 7.91 | 9.32 |
Rated Output (KW) | 0.15 | 0.29 | 0.44 | 0.61 | 0.78 | 0.98 | 1.18 | 1.43 | 1.73 |
Efficiency (%) | 0.0 | 48.5 | 63.2 | 69.4 | 70.0 | 71.8 | 71.3 | 68.5 | 64.8 |
Power Factor (%) | 17.3 | 32.5 | 46.1 | 56.9 | 66.2 | 71.2 | 75.2 | 78.6 | 80.7 |
Speed (RPM) | 1,800 | 1,781 | 1,768 | 1,757 | 1,740 | 1,726 | 1,710 | 1,690 | 1,655 |
Temp. Rise @ FL | 0.0 | 0.0 | 0.0 | 0.0 | 52.0 | 0.0 | 0.0 | 0.0 | 0.0 |
Torque (ft-lbs) | 0.00 | 8.90 | 17.80 | 26.90 | 36.00 | 45.40 | 55.10 | 65.10 | 75.80 |
Feature
- Premium Quality Explosion Proof Motor
- Meets All UL as Well as CSA Safety Requirements
- Uses Precision Double Shielded Bearings